Installation Instructions
22 Rim Device
This product is covered by the following patent numbers:
3,767,238 4,167,280 4,427,223 4,437,693 4,466,643
Devices covered by these instructions:
22 Rim Device
22-F Fire Exit Rim Device
1. Check hardware schedule for strikes, fasteners, and other special requirements.
2. Check carton label for trim, strikes, options, and order number.
3. Read all instructions, including instructions provided with any options used:
trim, alarm kit, glass bead kit, latch guard kit, and rod guard kit.
4. Gather special tools required: • #10-24 tap • 13/32” dia. drill bit
• #25 drill bit • Hacksaw
• 1/8” dia. drill bit 7/8” dia. hole saw
• 1/4” dia. drill bit
BEFORE STARTING INSTALLATION
Copyright © 2003 Ingersoll-Rand. All rights reserved.
911333_00(9)
VON DUPRIN
®
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - VON DUPRIN

Installation Instructions22 Rim DeviceThis product is covered by the following patent numbers:3,767,238 4,167,280 4,427,223 4,437,693 4,46

Page 2 - MAINTENANCE

911333_00(9) Page 10 of 12Metric Conversion Table1-9/16 401-11/16 431-3/4 452-1/4 5724-3/4 6291/16 21/8 33/16 51/4 613/32 107/16 111/2 135/8 163/4 197

Page 3 - 22/22-F PARTS LIST

911333_00(9) Page 11 of 12CENTER CASE TEMPLATERefer to Step 4 (p. 6)when using this templateTemplate to scale(dimensions in inches)STRIKE TEMPLATERefe

Page 4 - INSTALLATION

911333_00(9) Page 12 of 121-1/16”1-1/16”Cut on this line for 1409/1439 strikePrepare holes 4 places:Surface Application (no outside trim):Metal door:

Page 5

911333_00(9) Page 2 of 12GENERAL INFORMATIONReview pages 2 and 3 so you can identify the hardware and understand the terminology used in the instructi

Page 6 - Prepare door for device

911333_00(9) Page 3 of 1222/22-F PARTS LIST#10-24 x 3/4”machine screws (2)#10-24 x 1”machine screws (6)#10-24 x 1-1/8”machine screws (2)#10-24 x 1-1/2

Page 7 - 911333_00(9) Page 7 of 12

911333_00(9) Page 4 of 12RHR shownLHR opposite39-13/16”to finishedfloorLC1.1. Mark centerline C location as shown in Figure 1-1.1.2. For 299 or 299F s

Page 8 - 911333_00(9) Page 8 of 12

911333_00(9) Page 5 of 12Install strike. Use TWO SCREWS ONLY at this time.2DoorStopInstall strike flush with door sideof stop for 1409 and 1/16” pastd

Page 9 - 499F Strike Hook

911333_00(9) Page 6 of 123Cut device if necessary.If using ALK exit alarm option, installALK cover plate before cutting device.NOTE!TapeCover platePus

Page 10 - Metric Conversion Table

911333_00(9) Page 7 of 12 Install device to door at center case.55.1. If using cylinder in trim, install tailpiece guide (packaged with trim) in devic

Page 11

911333_00(9) Page 8 of 12 Install mechanism case mounting bracket and mechanism case end cap.6If necessary, add strike adjusting shim under strike for

Page 12 - 911333-00

911333_00(9) Page 9 of 12Prepare remaining strike mounting holes and install screws.8299 or 299F Strike499F StrikeStrike plate(299 strike only)Use scr